S-220 GSM GPRS Data Logger
Introduction:
The S2xx Serial GSM GPRS Telemetry Engine equipped Siemens MC55i quad-band GSM Module inside, is a low cost, M2M, data logger, universal GSM GPRS Engine which can transmit and receive analog, digital and pulse counter data, PLC, RS485 meter, Varity metering equipments to any device connected to the GSM/GPRS network such as mobile phones, Web Sites, SCADA, monitoring center, control room, etc.
S200/S220/S240 model list:
item |
Input ports |
Port |
Relay outputs |
Model |
Analog (0-5V or 4-20mA) |
Digital(NC/NO/EOL, or Pulse counter) |
Temperature (DS18B20) |
RS485 |
USB |
Dry contact (250V/3A) |
S200 |
4 |
2 |
2 |
1 |
1 |
2 |
S220 |
6 |
6 |
2 |
1 |
1 |
4 |
S240 |
10 |
6 |
2 |
1 |
1 |
4 |
Features:
● Direct connection to the GSM GPRS Network;
●Transparent Serial Data Tunneling using low cost SMS/GPRS network;
●Remote Configuration by SMS Messages or GPRS;
●Upload data via GPRS or SMS on Schedule or event occurs;
●Supports Dynamic Domain name or fixed IP address;
●Supports SMS, CSD, GPRS, UDP and TCP/IP protocols;
●Supports Modbus RTU protocols;
●1 RS485 Serial Ports for Modbus meter;
●UP TO 10 Analogue Inputs. (12 bit resolution, 0-5V or 4-20mA can be program by switches);
●UP TO 6 OPT Coupler (5-24V) Digital Inputs can be programmed to NC/NO/Edge/Level type by switch, OPT and NON OPT can be programmed by switch, when alarm occurs can send Alarm Messages by SMS or GPRS or auto dial the preset phone numbers;
●UP TO 6 digital inputs can be used as Pulse Counters;
●UP TO 4 OPT Digital Outputs can be programmed as dial to switch on/off with free communication fee, alarm-linkage and Schedule to action, also can be send SMS to switch on/off;
●UP TO 4 Digital Relay Outputs :120VAC/3A, 24VDC /3A, Can be controlled by Event, scheme, Incoming call, SMS Commands, Timer, Interlock; 2 outputs can setup as NC or NO type;
●User friendly PC Programming Interface, it can remotely program the terminals as well as to upload the data from the terminals by SMS or GPRS, all of the Current Value or status of the terminal can be display directly, and also will display the SMS Command details while you programming it;
Suitable for:
●Environmental
●Pumping station
●Oilfield
●Gas data acquisition
●Power Station
●Water level
●Rain gauge
●Urban water supply pipe network
●Reservoir
●Meter reading system
●Sewage treatment
●Transformer
PC Programming Software:
With this programmer software, users can setting all the I/O ports, administrator id, data transferring, and GPRS connection, IP address parameters, meanwhile, manual/auto require data from S200s via GPRS network is available.
Specifications:
Parameter Item |
Reference Scope |
DC Power supply |
Standard adapter: DC 12V/1.5A Reference scope 9-24V DC |
Power consumption |
Standby:12V/70mA; Working Max.: 12V/300mA |
GPRS Module |
Siemens MC55i |
Frequency bands |
Quad-band: EGSM 850,EGSM900, GSM 1800, GSM 1900, Compliant to GSM Phase 2/2+ |
Transmit power |
Class 4 (2W) at EGSM 900 and EGSM 850; Class 1 (1W) at GSM 1800 and GSM 1900 |
GPRS connectivity |
GPRS multi-slot class 10 |
GPRS Data Transmission |
GPRS data downlink transfer: max. 85.6 kbps; GPRS data uplink transfer: max. 42.8 kbps. |
TCP/IP stack |
TCP,UDP |
SIM interface |
Supporting 3V SIM Card |
External antenna |
Connected via 50 Ohm antenna connector or antenna pad, SMA Antenna interface |
Serial Interfaces |
1 RS485 Port for Modbus meter, 1 USB Port for PC programmer; |
Protocols |
SMS, GPRS UDP, TCP, Modbus RTU, and more equipment protocols can be added according to requirements. |
Digital Inputs |
UP TO 6 OPT Coupler (Active Contact 3-24V);NC/NO/Edge/Level type; Active Contact and Passive Contact By Switch; Can be used as Pulse Counters; |
Analog Inputs |
UP TO 10 Analog Inputs. 12 bit resolution, 0-5V or 0-20mA; |
Thermometer Inputs |
2 Ports for DS18B20, Measures temperatures from -55°C to +125°C. Fahrenheit equivalent is -67°F to +257°F, ±0.5°C accuracy from -10°C to +85°C, Thermometer resolution is 12 bits. |
Digital Relay Outputs |
UP TO 4, AC240V/3A, DC24V/10A, Can be controlled by Event, scheme, Incoming call, SMS Commands, Timer, Interlock; 2 outputs can setting as NC or NO type; |
Power Source Outputs |
3 Ports with 3.3VDC/400mA Power for external device; 1 Port with 12VDC/750mA Power for external device; |
Internal Backup Battery |
7.2v 1200mAH |
Work Temperature range |
-10-+70 °C |
Humidity range |
Relative humidity 95% (condensation free) |
Exterior dimension |
170mm*115mm*33mm |
Net Weight |
600~1000 g |
Packing List:
Main unit x1
AC/DC Power supply adapter x1 (AC 100~240V to
DC12V/2A, UK/AU/USA/EU type power plug available)
USB cable x1
CD disk (PC Configuration and User Manual) x1
GSM Antenna x1
Package Size:W300*D205*H75MM
Gross Weight:1.5KG
5Pcs per carton
Delivery & Shipping:
Our payment terms: T/T, Western Union, Paypal.
1. Delivery Time:
(1) Sample Order -- will be shipped within 2-4 working days after order and payment confirmation.
(2) Normal Order -- will be shipped within 3~7 working days after receiving payment.
Shipping Address: Please provide us with correct and detailed shipping Address.
2. Shipping Methods:
(1) Normally we delivery by Express such as DHL, UPS, EMS, TNT.
Around 3-7 working days to arrive.
(2) By air-express or ocean shipping is up to you.